Abstract
We have investigated optical read-out of uncoated polymer micrometer-sized cantilever sensors by self-mixing interference in VCSELs for single-molecule gas sensing. A resolution ~0.2 nm is measured, which is much better than current methods.
© 2009 Optical Society of America