Validation of a Monte Carlo Model for Determination of Fluorophore Concentration on Scattering Media

Not Accessible

Your library or personal account may give you access

Abstract

Experimental validation of a Monte Carlo code for correcting the effect of optical properties on fluorescence measurements is presented. The error for predicting true concentration was 4% and 10% for absorbing-only and turbid samples, respectively.

© 2012 Optical Society of America

PDF Article
More Like This
Monte Carlo Based Model of Fluorescence: Theory and Application to Breast Cancer Diagnosis

Gregory M. Palmer and Nirmala Ramanujam
SD9 Biomedical Topical Meeting (BIOMED) 2006

On the Validity of Assumptions to Incorporate Absorption in Monte Carlo Simulations

Katherine W. Calabro and Irving J. Bigio
BSu5A.3 Biomedical Optics (BIOMED) 2012

Accuracy of a Simple Diffusion Model of Fluorescence for Estimating Fluorophore Concentration

Kevin R. Diamond, Michael S. Patterson, and Thomas J. Farrell
5138_106 European Conference on Biomedical Optics (ECBO) 2003