Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Conference on Lasers and Electro-Optics/Quantum Electronics and Laser Science Conference and Photonic Applications Systems Technologies
  • Technical Digest (CD) (Optica Publishing Group, 2006),
  • paper CFL2

Sub-ppb monitoring of NO using wavelength modulation spectroscopy with a thermo-electrically cooled, cw QCL

Not Accessible

Your library or personal account may give you access

Abstract

We used a thermo-electrically cooled, continuous-wave, quantum cascade laser with wavelength modulation spectroscopy for the detection of nitric oxide at sub-part-per-billion volume (ppbv). The minimal detectable absorption achieved is 9 × 10-9 cm−1Hz−½.

© 2006 Optical Society of America

PDF Article
More Like This
Photoacoustic DFB-CW Quantum Cascade Laser based Nitric Oxide sensor for Breath Analyzer

N Sreevalsen, Vinode Rathore, and Alok J. Verma
Th3A.23 International Conference on Fibre Optics and Photonics (Photonics) 2016

Sub-ppbv atmospheric sensing of NO using wavelength modulation spectroscopy with a peltier-cooled, CW QCL

Bas W. Moeskops, Simon M. Cristescu, and Frans J. Harren
PDP_8 Laser Applications to Chemical, Security and Environmental Analysis (LACSEA) 2006

Nitric Oxide detection using Quantum Cascade Laser (QCL) for Atmospheric Monitoring and Medical Diagnostics

N. Sreevalsen, S. Chourasia, S. Patil, R. Agrawal, A. Singh, and A. J. Verma
S5A.26 International Conference on Fibre Optics and Photonics (Photonics) 2014