Efficiency of SHG at an incident intensity of I ≤ 1012 W/cm2 was investigated. This intensity level is achieved at the output of the high peak power MBI Ti:Sa laser facility direct in the recompressed beam. Thin (0.5-2 mm), large aperture (70 mm diameter) KDP crystals was used in experiments. Highly efficient (> 40%) conversion of 50 femtosecond Ti:Sa laser pulses to the second harmonics is shown.
© 2001 EPS
PDF ArticleMore Like This
M.P. Kalachnikov, V.B. Karpov, H. Söhdnnagel, I.A. Begishev, V.V. Korobkin, P.V. Nickles, and W. Sandner
HIFLA134 The European Conference on Lasers and Electro-Optics (CLEO/Europe) 2001
M.P. Kalachnikov, K.A. Janulewicz, P.V. Nickles, P.J. Warwick, I. Will, and W. Sandner
JThB1 European Quantum Electronics Conference (EQEC) 1998
Makoto Aoyama, Tetsuo Harimoto, Fumihiko Nakano, Yutaka Akahane, and Koichi Yam Akawa
WJ2_6 Conference on Lasers and Electro-Optics/Pacific Rim (CLEO/PR) 2001