Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

High sensitivity miniature Mach-Zehnder-interferometer using micro-abrupt-tapers in a cladding-depressed strongly guiding fiber for a picoliter-volume microsensing

Not Accessible

Your library or personal account may give you access

Abstract

We demonstrate miniature Mach-Zehnder-interferometer with a device length of 179.5 μm using two micro-abrupt-tapers in a cladding-depressed strongly-guiding fiber. The index variation of 2×10−3 from a 6.3 picoliter optical liquid can cause 1.6 nm wavelength-shift.

© 2011 Optical Society of America

PDF Article
More Like This
High sensitivity tapered fiber Mach-Zehnder interferometer with optical attractive near-field force for active microsensing

Nan-Kuang Chen, Tsung-Hsun Yang, Yi-Ning Chen, Zhao-Ying Chen, and Shien-Kuei Liaw
JW2A.64 CLEO: Applications and Technology (CLEO:A&T) 2013

Towards picoliter microsensing in index and temperature using hundreds-micron-scale fiber Michelson interferometers

Nan-Kuang Chen, Shih-Hsin Lo, Chia-Lung Tsai, Santosh Kumar, Wood-Hi Cheng, and Raman Kashyap
JTh2A.112 CLEO: Applications and Technology (CLEO:A&T) 2017

Sensitivity-enhanced refractive index sensor by using tapered thin-core fiber based inline Mach-Zehnder interferometer

Jie Shi, Shilin Xiao, and Meihua Bi
83110C Asia Communications and Photonics Conference and Exhibition (ACP) 2011