Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

A novel optical detector concept for dedicated and multi-modality in vivo small animal imaging

Not Accessible

Your library or personal account may give you access

Abstract

An optical detector suitable for inclusion in tomographic arrangements for non-contact in vivo bioluminescence and fluorescence imaging applications is proposed. It consists of a microlens array (MLA) intended for field-of-view definition, a large-field complementary metal-oxide-semiconductor (CMOS) chip for light detection, a septum mask for cross-talk suppression, and an exchangeable filter to block excitation light. Prototype detector units with sensitive areas of 2.5 cm × 5 cm each were assembled. The CMOS sensor constitutes a 512 × 1024 photodiode matrix at 48 pm pixel pitch. Refractive MLAs with plano-convex lenses of 480 pm in diameter and pitch were selected resulting in a 55 × 105 lens matrix. The CMOS sensor is aligned on the focal plane of the MLA at 2.15 mm distance. To separate individual microlens images an opaque multi-bore septum mask of 2.1mm in thickness and bore diameters of 400 pm at 480 pm pitch, aligned with the lens pattern, is placed between MLA and CMOS. Intrinsic spatial detector resolution and sensitivity was evaluated experimentally as a function of detector-object distance. Due to its small overall dimensions such detectors can be favorably packed for tomographic imaging (optical diffusion tomography, ODT) yielding complete 2 ` field-of-view coverage. We also present a design study of a device intended to simultaneously image positron labeled substrates (positron emission tomography, PET) and optical molecular probes in small animals such as mice and rats. It consists of a cylindrical allocation of optical detector units which form an inner detector ring while PET detector blocks are mounted in radial extension, those gaining complementary information in a single, intrinsically coregistered experimental data acquisition study. Finally, in a second design study we propose a method for integrated optical and magnetic resonance imaging (MRI) which yields in vivo functional/molecular information that is intrinsically registered with the anatomy of the image object.

© 2007 SPIE

PDF Article
More Like This
High-resolution image acquisition using a compact microlens-coupled detector

Daniel Unholtz, Ralf B. Schulz, Wolfhard Semmler, and Jörg Peter
6631_53 European Conference on Biomedical Optics (ECBO) 2007

A microlens based optical imaging (OI) insert for bimodal OI-MRI imaging

Steffen Paar and Jörg Peter
BM3A.44 Biomedical Optics (BIOMED) 2014

Simultaneous PET and 3D Fluorescence Optical Tomography for Small Animal Imaging: In vivo Results and System Improvements

Changqing Li, Julien Bec, and Simon R. Cherry
BMB6 Biomedical Optics (BIOMED) 2010

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.