Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Combining near-infrared spectroscopy with electroencephalography and repetitive transcranial magnetic stimulation

Not Accessible

Your library or personal account may give you access

Abstract

The objective of the study was to assess the usability of a near-infrared spectroscopy (NIRS) device in multimodal measurements. We combined NIRS with electroencephalography (EEG) to record hemodynamic responses and evoked potentials simultaneously, and with transcranial magnetic stimulation (TMS) to investigate hemodynamic responses to repetitive TMS (rTMS). Hemodynamic responses and visual evoked potentials (VEPs) to 3, 6, and 12 s stimuli consisting of pattern-reversing checkerboards were successfully recorded in the NIRS/EEG measurement, and ipsi- and contralateral hemodynamic responses to 0.5, 1, and 2 Hz rTMS in the NIRS/TMS measurement. In the NIRS/EEG measurements, the amplitudes of the hemodynamic responses increased from 3- to 6-s stimulus, but not from 6- to 12-s stimulus, and the VEPs showed peaks N75, P100, and N135. In the NIRS/TMS measurements, the 2-Hz stimulus produced the strongest hemodynamic responses compared to the 0.5- and 1-Hz stimuli. In two subjects oxyhemoglobin concentration decreased and in one increased as a consequence of the 2-Hz rTMS. To locate the origin of the measured NIRS responses, methods have to be developed to investigate TMS-induced scalp muscle contractions. In the future, multimodal measurements may prove useful in monitoring or treating diseases such as stroke or Alzheimer’s disease.

© 2009 OSA/SPIE

PDF Article
More Like This
Effects of Transcranial Magnetic Stimulation on Cerebral Hemodynamics Measured by Diffuse Correlation & Optical Spectroscopies

R. C. Mesquita, M. N. Kim, E. M. Buckley, P. Turkeltaub, A. L. Thomas, O. K. Faseyitan, M. Tobita, J.A. Detre, A.G. Yodh, and R. Hamilton
JMA86 Biomedical Optics (BIOMED) 2010

Frontal Activation Assessment Using Near-Infrared Spectroscopy and Electroencephalography

Jing Dong, Chidambaram Yegappan, Renzhe Bi, and Kijoon Lee
JM3A.48 Biomedical Optics (BIOMED) 2012

Cerebral blood flow is reduced by neuronal inhibition induced by transcranial magnetic stimulation – A none-invasive functional optical imaging study on adults

J. Steinbrink, C. Koehnke, M. Voss, K. Irlbacher, S. Boden, A. Villringer, H. Obrig, R. Wenzel, and M. Kohl
FE3 Biomedical Topical Meeting (BIOMED) 2004

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.