A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy

Not Accessible

Your library or personal account may give you access

Abstract

The aim of this work is to obtain improved sectioning ability in our slit-scanning microscope. The experimental setup is based on a linear sensor and different illumination modes were evaluated. MTF measurements from USAF target images showed the great benefit of using slit illumination in comparison to widefield. Experimental determination of Strehl ratios of 0.62 and 0.96 for wide-field and slit-illumination configurations, respectively, is depicted. Also MTF degradation with defocus is fairly established as stated by Strehl ratio decrease from 0.68 to 0.59 in 2 μm defocus using widefield configuration. Experimental measurement of axial response showed good accordance to numerically simulated curves modeled for the same parameters as the experimental setup. Linear sensor microscopy shows its advantage in comparison to simple slit microscopy particularly for slit illumination. Imaging for details running in sensor direction is accomplished for parallel illumination and detection slits as well as effective axial response for right-angled slits. These results indicate that linear sensor microscopy should be able to surpass lateral resolution asymmetry of slit microscopy. Preliminary results from tests to develop a reconstruction method that combine algorithms to improve lateral resolution isotropy of 2D images and those to build 3D images will be presented.

© 2011 OSA/SPIE

PDF Article
More Like This
3D reconstruction methods using line-scanning microscopy with a linear sensor

Milton P. Macedo and C. M. B. A. Correia
87970J European Conference on Biomedical Optics (ECBO) 2013

Development and assessment of image reconstruction algorithms using a low-cost bench-microscope based on a linear CMOS image sensor

M. P. Macedo and C. M. B. A. Correia
7367_1F European Conference on Biomedical Optics (ECBO) 2009

Evaluation of a new method for the determination of experimental PSF of a wide-field microscope using white-light and a linear sensor

Milton P. Macedo, Antonio J. Barata, Ana G. Femandes, and Carlos M. Correia
6630_43 European Conference on Biomedical Optics (ECBO) 2007

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.