In vivo study of partial liver resection on pigs using a 1.9 μm Thulium fiber laser

Not Accessible

Your library or personal account may give you access

Abstract

Dissection of liver tissue can be performed by different techniques (ultrasound, mono and bipolar dissection, water jet dissection and by stapler). In this animal study the potential of a Thulium fiber laser system was investigated for open parenchyma dissection.

Based on a cw Thulium fiber laser (IPG laser GmbH, Burbach, Germany), emitting a wavelength at 1.9 μm and a maximal power at 50 W, a surgical dissection device was developed at the Medical Laser Centre Luebeck. Cw laser radiation (40 Watt) was transmitted via a 365 μm fiber with a polished distal fiber tip. Procedure was performed in contact mode; irradiance at the distal fiber tip was 38.2 kW/cm2. After general anesthesia and a median laparotomy an atypical laser resection of the liver was performed in 3 pigs. Healing process was controlled after 2-3 weeks by histological analysis (H&E staining). The final evaluation data included total resection time, blood loss, bile leakage and mass of dissected tissue. All animals treated in this study were cared for in accordance to the European convention on animal care.

In general the dissection with the 1.9 μm laser radiation was easily performed. Hemostasis was highly sufficient so blood loss and bile leakage was negligible. Total resection time including hemostasis of the remaining tissue was 26 ± 12 min. Weight of resected tissue was 17 ± 8 g. During survival period no complications (bleeding or inflammation) occurred. After 2 weeks histology showed ongoing scar formation about 1 – 2 mm in depth of the dissected area.

© 2011 OSA/SPIE

PDF Article
More Like This
Partial porcine kidney resection in vivo using a 1.92 μm fiber laser system

Dirk Theisen-Kunde, Sönke Tedsen, Veit Danicke, and Ralf Brinkmann
7373_1B European Conference on Biomedical Optics (ECBO) 2009

Partial Kidney Resection Based on 1.94 μm Fiber Laser System

D. Theisen-Kunde, S. Tedsen, K. Herrmann, V. Danicke, and R. Brinkmann
6632_4 European Conference on Biomedical Optics (ECBO) 2007

Clinical evaluation of thulium laser / ultrasonic aspirator combination instrument during neurosurgical tumour resection

Dirk Theisen-Kunde, Jessica Kren, Alessa Hutfilz, Matteo Mario Bonsanto, and Ralf Brinkmann
126270Z European Conference on Biomedical Optics (ECBO) 2023