Three-Dimensional Cortex Model Including Vascular Structure for Estimation of Path Length for Optical Imaging

Not Accessible

Your library or personal account may give you access

Abstract

Optical imaging of hemoglobin concentration changes in the exposed cortex has been used to investigate the functional brain activation. The concentration changes in oxygenated and deoxygenated hemoglobin can be independently obtained from the dual- or multi-wavelength measurements of the change in reflectance of the exposed cortex and wavelength-dependent optical path length in the cortical tissues. In the previous studies, the partial optical path length were generally estimated by homogeneous and layered models. In reality, the concentration changes in the hemoglobin only occurs in the blood vessels. In this study, the partial optical path lengths in the blood vessels were estimated by the heterogeneous model including the blood vessel structure based upon the image acquired by two-photon microscopy. Light propagation in the exposed-cortex model is simulated to estimate the wavelength dependence of the partial optical path length in the blood vessels. The wavelength dependence of the partial optical path length for the heterogeneous model was different from that for the homogeneous model. In the wavelength range from 500 to 580 nm, the partial optical path length in the blood vessels was mainly affected by the structure of the blood vessels in the region shallower than 50 μm.

© 2013 SPIE

PDF Article
More Like This
Path Length Correction in Exposed-Cortex Optical Imaging using 3D Model Obtained by Two-Photon Microscopy

Eiji Okada, Takahiro Kikuchi, Yu Yoshimori, Hiroyuki Takuwa, Hiroshi Kawaguchi, Kazuto Masamoto, and Hiroshi Ito
BM3A.12 Biomedical Optics (BIOMED) 2014

Estimation of the optical path length factor for functional imaging of an exposed cortex by principal component analysis

Kentaro Yokoyama, Motoshi Watanabe, and Eiji Okada
5138_168 European Conference on Biomedical Optics (ECBO) 2003

Path-length correction for the haemoglobin-concentration measurement using the skull cranial window by multi-spectral imaging analysis

Koichiro Sakaguchi, Shunsuke Furukawa, Takushige Katsura, Kyoko Yamazaki, Hideo Kawaguchi, Atsushi Maki, and Eiji Okada
6629_19 European Conference on Biomedical Optics (ECBO) 2007

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved