Concept for Tremor Compensation for a Handheld OCT-Laryngoscope

Not Accessible

Your library or personal account may give you access

Abstract

Optical coherence tomography (OCT) is a non-invasive imaging technique which can create optical tissue sections, enabling diagnosis of vocal cord tissue. To take full advantage from the non-contact imaging technique, OCT was adapted to an indirect laryngoscope to work on awake patients. Using OCT in a handheld diagnostic device the challenges of rapid working distance adjustment and tracking of axial motion arise. The optical focus of the endoscopic sample arm and the reference-arm length can be adjusted in a range of 40 mm to 90 mm. Automatic working distance adjustment is based on image analysis of OCT B-scans which identifies off depth images as well as position errors. The movable focal plane and reference plane are used to adjust working distance to match the sample depth and stabilise the sample in the desired axial position of the OCT scans. The autofocus adjusts the working distance within maximum 2.7 seconds for the maximum initial displacement of 40 mm. The amplitude of hand tremor during 60 s handheld scanning was reduced to 50 % and it was shown that the image stabilisation keeps the position error below 0.5 mm. Fast automatic working distance adjustment is crucial to minimise the duration of the diagnostic procedure. The image stabilisation compensates relative axial movements during handheld scanning.

© 2013 SPIE

PDF Article
More Like This
A laryngoscope for office-based imaging of human vocal folds using OCT

H. Wisweh, N. Rohrbeck, A. Krüger, M. Kraft, K. Aleksandrov, and H. Lubatschowski
7372_0I European Conference on Biomedical Optics (ECBO) 2009

Real-Time Three-Dimensional Imaging of Larynx Using a Swept-Source Optical Coherence Tomography (SS-OCT) System Consisting of a GRIN Lens Rod-Based Probe and a High Speed VCSEL Laser Source

Swathi Rangarajan, Li-dek Chou, Giriraj Sharma, Christian Barnes, Brian J-F. Wong, and Ram Ramalingam
JTu3A.15 Cancer Imaging and Therapy (Cancer) 2016

In-vivo imaging of keratoconic corneas using high-speed high-resolution swept-source OCT

S. Marschall, A. Gawish, Y. Feng, L. Sorbara, P. Fieguth, and K. Bizheva
88020P European Conference on Biomedical Optics (ECBO) 2013

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.