Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Evaluation of arthritis with model rats using photoacoustic imaging system

Not Accessible

Your library or personal account may give you access

Abstract

Associated with local articular rigidity, swelling and pain as well as systemic development of fever and a sense of fatigue, arthritis is a disorder causing deterioration of patients’ quality of life. Approximately 300,000 patients report rheumatoid arthritis, one of the typical chronic joint inflammation, in Japan alone: 1% of the world’s population has the disorder worldwide. Although X-ray CT, MRI, and ultrasonic Doppler method are used for examination and diagnosis, various problems exist such as radiation exposure, administration of contrast agents and difficulty in earlier diagnosis and quantitative evaluation. To resolve these difficulties, we developed a handheld photoacoustic imaging system. In this study, the feasibility of evaluating the degree of inflammation using photoacoustic imaging with multiple wavelengths was investigated with in vivo measurements of model rats. The changes in signal intensity depending on the presence or absence of the disorder was examined. It was confirmed that the signal intensity can be intensified at diseased joints. Then, the changes with different time elapsed from drug administration was examined using rats. It was clarified that the degree of inflammation can be evaluated by shapes of photoacoustic spectra, which changed along with the progress of the inflammation. Through these analyses, we verified the usefulness of photoacoustic imaging for the diagnosis and evaluation of arthritis.

© 2019 SPIE/OSA

PDF Article
More Like This
Fluorescence imaging of experimental rheumatoid arthritis in vivo using a fast flying-spot scanner

J. Berger, J. Voigt, F. Seifert, B. Ebert, R. Macdonald, I. Gemeinhardt, O. Gemeinhardt, J. Schnorr, M. Taupitz, A. Vater, S. Vollmer, K. Licha, and M. Schirner
6631_32 European Conference on Biomedical Optics (ECBO) 2007

High resolution 3D photoacoustic scanner for clinical vascular imaging: application to the assessment of inflammatory arthritis

Nam Huynh, Olivia Francies, Jessica Manson, Jiaqi Zhu, Edward Zhang, Ben Cox, Andrew Plumb, and Paul Beard
TTu4B.2 Clinical and Translational Biophotonics (Translational) 2022

Deep Neural Networks Improve Diagnostic Accuracy of Rheumatoid Arthritis using Diffuse Optical Tomography

Hamid Dehghani, Yangqin Feng, Daniel Lighter, Lei Zhang, and Yan Wang
11074_52 European Conference on Biomedical Optics (ECBO) 2019

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.