Abstract
In order to detect fiber faults before communication service is affected, a test and measurement system using a maintenance-band wavelength of 1.6–1.7 μm has been proposed,1·2 but has not been built. We have experimentally clarified correlations between 1.65-μm and 1.31/1.55-μm losses in both optical subscriber lines using standard fibers and trunk lines using dispersion-shifted fibers in the field. Thus a 1.65-μm surveillance and test system is presented.
© 1994 Optical Society of America
PDF ArticleMore Like This
Nobuo Tomita
17C1.1 Optoelectronics and Communications Conference (OECC) 1996
Kenji Okada
TUQ30 Optical Fiber Communication Conference (OFC) 1985
Yasuyuki Okumura
TuE4 Optical Fiber Communication Conference (OFC) 1994