Abstract
We report the thermal sensitivity dependence of a cascaded long period grating on the external medium refractive index. The device thermal sensitivity, waveguide dispersion factor and thermo-optic coefficient in the presence or air, water and alcohol are obtained. Changes in the thermo-optic coefficient due variations in the external refractive index are the main cause of changes in the thermal sensitivity.
© 2006 IEICE