Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Graphene oxide diaphragm for acoustic fiber sensing

Not Accessible

Your library or personal account may give you access

Abstract

A fiber sensor composed by a graphene oxide membrane at the tip of a capillary is presented. The graphene oxide membrane acts as a low-reflectivity mirror, distanced from a single mode fiber forming a low finesse Fabry-Perot interferometer. The response of the sensor to acoustic pressure with varying frequency is studied in the range between 5 and 45 kHz, attaining a minimum signal to noise ratio of 14 dB.

© 2020 The Author(s)

PDF Article
More Like This
Graphene Diaphragm-based Extrinsic Fabry-Perot Interferometer for Low Frequency Acoustic Sensing

Wenjun Ni, Ping Lu, Deming Liu, and Jiangshan Zhang
s2212 Conference on Lasers and Electro-Optics/Pacific Rim (CLEO/PR) 2017

Multi-layer Graphene Diaphragm-based Fabry-Perot Interferometer for Acoustic Detection with Long Term Stability

Congzhe Zhang, Yuanhong Yang, Yanzhen Tan, Jun Ma, Hoi Lut Ho, and Wei Jin
Tu3A.5 Asia-Pacific Optical Sensors Conference (APOS) 2016

Lens-less, Spring-Loaded Diaphragm-Based Fiber Acoustic Sensor

Behrad Habib Afshar and Michel J. F. Digonnet
WD6 Optical Fiber Sensors (OFS) 2018

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.