Complete Characterization of an OPCPA at High Repetition Rate Using Frequency Resolved Optical Switching

Not Accessible

Your library or personal account may give you access

Abstract

We show that frequency resolved optical switching (FROSt) can be used for full characterization of high repetition rate optical parametric chirped-pulse amplifiers (OPCPA). We characterize supercontinuum seed pulses at up to 500 kHz followed by the tunable near-infrared output signal and idler, simultaneously, of an ytterbium-based OPCPA system.

© 2023 UFOXIII

PDF Article
More Like This
Temporal Characterization of a Supercontinuum at 500 kHz Repetition Rate Using Frequency Resolved Optical Switching

Elissa Haddad, Adrien Longa, Philippe Lassonde, Adrien Leblanc, Heide Ibrahim, François Légaré, and Gaëtan Jargot
W4A.37 International Conference on Ultrafast Phenomena (UP) 2022

High repetition rate OPCPA driving an attosecond pump-probe beamline

Federico J. Furch, Tobias Witting, Mikhail Osolodkov, Felix Schell, Claus P. Schulz, and Marc J. J. Vrakking
HF1B.1 High Intensity Lasers and High Field Phenomena (HILAS) 2020

Verifying the Frequency Resolved Optical Switching Technique to Accurately Characterize Multi-Octave IR Pulse

Adrien Longa, Mayank Kumar, Philippe Lassonde, Antoine Laramée, Heide Ibrahim, François Legaré, and Adrien Leblanc
FF3N.3 CLEO: QELS_Fundamental Science (CLEO:FS) 2022