Analysis of long-term visual quality with numerical 3D ray tracing after corneal crosslinking treatment

Not Accessible

Your library or personal account may give you access

Abstract

A numerical 3D ray tracing model was used to evaluate the long-term visual effects of two regimens of corneal crosslinking (CXL) treatment of 48 patients with the corneal degeneration keratoconus. The 3D ray tracing analyses were based on corneal elevation data measured by Scheimpflug photography. Twenty-two patients were treated with standard CXL applied uniformly across the corneal surface, whereas 26 patients underwent a customized, refined treatment only at local zones on the cornea (photorefractive intrastromal CXL; PiXL). Spot diagrams, spot root-mean-square (RMS) values, and Strehl ratios were evaluated for the patients prior to and 1, 3, 6, and 12 months after treatment. It was found that the group of patients treated with PiXL, on average, tended to attain a long-term improvement of the corneal optical performance, whereas only minor changes of the optical parameters were found for group treated with standard CXL. Our results confirmed that standard CXL treatment stabilizes the corneal optical quality over time, and thus halts the progression of the corneal degeneration. In addition to stabilization, the results showed that a significantly higher proportion of subjects treated with PiXL improved in RMS, 3, 6, and 12 months after treatment, compared to with CXL (p<0.05). This finding indicates that the PiXL treatment might improve optical quality over time.

© 2017 Optical Society of America

Full Article  |  PDF Article
More Like This
Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus

Staffan Schedin, Per Hallberg, and Anders Behndig
Appl. Opt. 55(3) 507-514 (2016)

Optimization of an intraocular lens for correction of advanced corneal refractive errors

Eddie Wadbro, Per Hallberg, and Staffan Schedin
Appl. Opt. 55(16) 4378-4382 (2016)

Supplementary Material (1)

NameDescription
Data File 1       Underlying data for Figs. 4 and 5.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (7)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (2)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved