Measurement of Polystyrene Nanospheres Using Excimer Laser Fragmentation Fluorescence Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Monodisperse polystyrene nanospheres with a mean diameter of 102 nm are photofragmented with 193 nm light in N<sub>2</sub> at laser fluences from 1 to 20 J/cm<sup>2</sup>. Carbon atom fluorescence at 248 nm from the disintegration of the particles is used as a signature of the polystyrene. The normalized fluorescence signals are self-similar with an exponential decay lifetime of ∼10 ns. At fluences above 17 J/cm<sup>2</sup>, optical breakdown occurs and a strong continuum emission is generated that lasts significantly longer. A non-dimensional parameter, the photon-to-atom ratio (PAR), is used to interpret the laser-particle interaction energetics. Carbon fluorescence from polystyrene particles is compared with that from soot, and a similarity between the two particles is observed when normalized with PAR. Carbon emission from bulk polystyrene was also measured. Similar emission signals were observed, but the breakdown threshold of the surface is significantly lower at 0.2 J/cm<sup>2</sup>.

PDF Article
More Like This
Soot particle disintegration and detection by two-laser excimer laser fragmentation fluorescence spectroscopy

Christopher B. Stipe, Donald Lucas, Catherine P. Koshland, and Robert F. Sawyer
Appl. Opt. 44(31) 6537-6544 (2005)

Atmospheric ammonia measurement using a VUV/photo-fragmentation laser-induced fluorescence technique

John S. Schendel, Robert E. Stickel, Cornelis A. van Dijk, Scott T. Sandholm, Douglas D. Davis, and John D. Bradshaw
Appl. Opt. 29(33) 4924-4937 (1990)

Measurements of extrinsic fluorescence in Intralipid and polystyrene microspheres

Vinh Nguyen Du Le, Zhaojun Nie, Joseph E. Hayward, Thomas J. Farrell, and Qiyin Fang
Biomed. Opt. Express 5(8) 2726-2735 (2014)