Spatially Multiplexed Imaging: Fluorescence Correlation Spectroscopy for Efficient Measurement of Molecular Diffusion at Solid–Liquid Interfaces

Not Accessible

Your library or personal account may give you access

Abstract

Fluorescence correlation spectroscopy (FCS) has become an important technique for the characterization of molecular dynamics, especially at interfaces. Fluorescence correlation spectroscopy provides both temporal and spatial resolution for measuring fast processes at equilibrium through analysis of noise in fluorescence intensities from the statistical fluctuations in a small number of molecules. The small molecular populations produce very low-level fluorescence signals, where time-averaging the fluorescence autocorrelation function is needed to generate reasonable signal-to-noise (S/N) ratios. Recently imaging cameras have been adapted to FCS measurements of molecular dynamics at interfaces (membranes and surfaces) through the use of electron-multiplying charge-coupled device (EM-CCD) detectors for acquisition of fluorescence from addressable areas on the detector. This approach provides a major advantage over traditional focused-spot FCS by allowing electronic control over the location and area of the acquired region on the sample surface. Imaging-FCS can also provide a spatial multiplexing advantage through its ability to measure intensity data from larger areas in parallel with no loss of time resolution. In this work, this multiplexing advantage is exploited to determine molecular diffusion rates from the simultaneous measurement of multiple areas on a surface, the autocorrelation traces from which are averaged to improve the S/N ratio. As proof of concept, the diffusion of 1,1′-dioctadecyl-3,3,3′3′-tetramethylindocarbocyanine perchlorate (DiI) on a C18-modified interface was measured using this multiplexed method and compared to autocorrelation data acquired from a single spot. Due to the slow thermal recovery of the EM-CCD that inhibits fast time-averaging, spatial multiplexing in imaging-FCS provides an eightyfold time savings to reach the same S/N ratio as multiple (time-averaged) measurements from a single spot.

© 2016 The Author(s)

PDF Article
More Like This
Electron multiplying CCD based detection for spatially resolved fluorescence correlation spectroscopy

Markus Burkhardt and Petra Schwille
Opt. Express 14(12) 5013-5020 (2006)

Single Plane Illumination Fluorescence Correlation Spectroscopy (SPIM-FCS) probes inhomogeneous three-dimensional environments

Thorsten Wohland, Xianke Shi, Jagadish Sankaran, and Ernst H.K. Stelzer
Opt. Express 18(10) 10627-10641 (2010)

Measuring and imaging diffusion with multiple scan speed image correlation spectroscopy

Nadine Gröner, Jérémie Capoulade, Christoph Cremer, and Malte Wachsmuth
Opt. Express 18(20) 21225-21237 (2010)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved