Abstract
We investigated the effect of amplitude-modulated (AM) ultrasound (US) on acousto-optic (AO) signals. A phantom was exposed to both AM US and a green laser, and CCD measurements of speckle contrast were made with various exposure times. The results show that the AO signal oscillates at the AM frequency when the CCD exposure time is a fraction of the AM period and stops oscillating when the CCD exposure time is a multiple of the AM period. The AO signal decreases quickly as the AM frequency increases or peak–peak (pk–pk) amplitude decreases. With exposure time, AM frequency and pk–pk acoustic pressure, there is an ~30% increase in the AO signal compared with that of CW US. The increase in the signal is likely to be due to the particle oscillation and the induced shear wave as a result of the radiation force generated by the AM US.
© 2010 Optical Society of America
Full Article | PDF ArticleMore Like This
Rui Li, Daniel S. Elson, Chris Dunsby, Robert Eckersley, and Meng-Xing Tang
Opt. Express 19(8) 7299-7311 (2011)
Roger J. Zemp, Chulhong Kim, and Lihong V. Wang
Appl. Opt. 46(10) 1615-1623 (2007)
Chulhong Kim, Roger J. Zemp, and Lihong V. Wang
Opt. Lett. 31(16) 2423-2425 (2006)