Abstract
A novel magnetic field fiber sensor based on magnetic fluid is proposed. The sensor is configured as a Sagnac interferometer structure with a magnetic fluid film and a section of polarization maintaining fiber inserted into the fiber loop to produce a sinusoidal interference spectrum for measurement. The output interference spectrum is shifted as the change of the applied magnetic field strength with a sensitivity of 16.7 pm/Oe and a resolution of 0.60 Oe. The output optical power is varied with the change of the applied magnetic field strength with a sensitivity of 0.3998 dB/Oe.
©2012 Optical Society of America
Full Article | PDF ArticleMore Like This
Peng Zu, Chi Chiu Chan, Lew Wen Siang, Yongxing Jin, Yifan Zhang, Liew Hwi Fen, Lihan Chen, and Xinyong Dong
Opt. Lett. 36(8) 1425-1427 (2011)
Longfeng Luo, Shengli Pu, Jiali Tang, Xianglong Zeng, and Mahieddine Lahoubi
Opt. Express 23(14) 18133-18142 (2015)
Xianli Li and Hui Ding
Opt. Lett. 37(24) 5187-5189 (2012)