Abstract
The literature describes more than 30 measurements, at wavelengths
between 249 and 1550 nm, of the absolute value of the nonlinear
refractive-index coefficient of fused silica. Results of these
experiments were assessed and best currently available values were
selected for the wavelengths of 351, 527, and 1053 nm. The best
values are (3.6 ± 0.64) × 10-16
cm2/W at 351 nm, (3.0 ± 0.35) ×
10-16 cm2/W at 527 nm, and (2.74 ±
0.17) × 10-16 cm2/W at 1053
nm.
© 1998 Optical Society of America
Full Article |
PDF Article
More Like This
References
You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or
Login to access Optica Member Subscription
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or
Login to access Optica Member Subscription
Figures (2)
You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or
Login to access Optica Member Subscription
Tables (2)
You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or
Login to access Optica Member Subscription