Large-aperture high-resolution x-ray collimator for the Solar Maximum Mission

Not Accessible

Your library or personal account may give you access

Abstract

A description is presented of a flight-qualified large-aperture 12 × 12-sec of arc angular resolution multigrid x-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4–22.4-Å wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. One advantage of this scheme is to provide ready access to the grid subassemblies for inspection and/or servicing. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. Aluminum is a viable material choice in this application because of the good thermal control expected in the SMM instrument package. The grids are of a compound and bimetallic design, having 63.5-μm square holes on an 88.9-μm spacing in 8-μm thick gold, which is in turn supported by a 76-μm thick Invar grid having 600-μm square holes on a 739-μm spacing. The small apertures in the gold provide the 12-sec of arc collimation with the Invar grids providing wide angle off-axis blocking out to an ~35-min of arc view angle. The collimator has seven individual channels, four of a 5.1- × 10-cm area and three of a 1.3- × 10-cm area. Laboratory measurements gave an average angular resolution of 12.5-sec of arc FWHM with 0.259 transmission for the large area channels and 12.0 sec of arc and 0.200 transmission for the small area channels. A hypothetical perfectly aligned collimator would have 12.5-sec of arc resolution and 0.300 transmission. A thermal filter composed of two layers of ~1000-Å thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the x radiation in the band of interest. The filter was flight qualified by passing a protoflight acoustic test environment of 147-dB total sound level, 20-μN/M2 reference, for 1-min duration.

© 1980 Optical Society of America

Full Article  |  PDF Article
More Like This
Optical alignment of an x-ray collimator

R. Hoekstra, T. E. d’Arnaud, and H. F. van Beek
Appl. Opt. 20(20) 3630-3634 (1981)

Large area x-ray collimator—the zone plate approach

Benedikt Menz, Christoph Braig, Heinrich Bräuninger, Vadim Burwitz, Gisela Hartner, and Peter Predehl
Appl. Opt. 54(26) 7851-7858 (2015)

Efficiency and resolution measurements of x-ray transmission gratings between 7.1 and 304 Å

A. C. Brinkman, J. H. Dijkstra, W. F. P. A. L. Geerlings, F. A. van Rooijen, C. Timmerman, and P. A. J. de Korte
Appl. Opt. 19(10) 1601-1605 (1980)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (10)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (5)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved