Abstract
The effects of ionizing radiation have been investigated in a series of materials commonly used in optical interferometric devices. Included in the study were three glass–ceramics (Zerodur, Cer-Vit 101, and Cer-Vit 142) and one Faraday-rotator glass (SF-57). Each glass–ceramic was irradiated at room temperature with 1.5-MeV electrons from a Van De Graaff accelerator. Similar irradiations were done on the Faraday-rotator glass at room temperature and 77 K. Optical absorption and electron spin resonance measurements provided a monitor of the radiation-induced point defects in all cases. The spectral characteristics and the production and thermal annealing behavior of these defects are described, and their possible effect on the performance of optical devices which incorporate these materials is considered.
© 1986 Optical Society of America
Full Article | PDF ArticleMore Like This
Jean M. Bennett, Joseph J. Shaffer, Yukio Shibano, and Yoshiharu Namba
Appl. Opt. 26(4) 696-703 (1987)
C. A. Nicoletta and A. G. Eubanks
Appl. Opt. 11(6) 1365-1370 (1972)
D. R. Olson, H. D. Dieselman, and J. B. Schroeder
Appl. Opt. 10(1) 81-86 (1971)