Abstract
We demonstrate a refractive micr-optical system by using ion-exchange microlenses and microprisms, which are combined to generate a superposition of two shifted images. The microlenses, fabricated with field-assisted Ag–Na exchange, achieve diffraction-limited imaging with a single-lens system and with a double-lens system for a field of 800 μm × 800 μm. Furthermore, we demonstrate cascading of two separate differential-pair optical-thyristor arrays by transcribing the information of a source array onto a second destination array.
© 1996 Optical Society of America