Abstract
A two-color pyrometric technique was developed for the in situ simultaneous measurement of individual fuel-particle temperatures and sizes in a pressurized entrained flow reactor (PEFR). A method that requires only a single optical port was developed, and a specially designed optical probe was manufactured for the measurements at the PEFR. The fuel-particle temperature was obtained by applying two-color pyrometry. The particle size was determined from the same pyrometric signals. A discrimination method was developed to confirm that the detected particle was valid for particle sizing. Several series of measurements were made at a PEFR at different process conditions, and some typical results are shown.
© 1997 Optical Society of America
Full Article | PDF ArticleMore Like This
Timo Joutsenoja and Rolf Hernberg
Appl. Opt. 37(16) 3487-3493 (1998)
Pal Toth, Teri Draper, Arpad B. Palotas, Terry A. Ring, and Eric G. Eddings
Appl. Opt. 54(15) 4916-4926 (2015)
M. Schiemann, N. Vorobiev, and V. Scherer
Appl. Opt. 54(5) 1097-1108 (2015)