Calibration of subnanometer motion with picometer accuracy

Not Accessible

Your library or personal account may give you access

Abstract

We have developed a method for calibrating subnanometer movements of a piezoelectric actuator with picometer accuracy and for a wide range of frequencies. This range make this calibration useful for scanning probe microscopes, particularly for an apertureless scanning near-field optical microscope in which the tip is dithered to modulate the optical signal. The setup consists of a Michelson interferometer that has a mobile arm capable of moving more than one fringe. The piezoelectric actuator to be calibrated vibrates at the desired frequency in the other arm. Net displacement can be calculated by simultaneous measurement of an interferometric signal and its derivative. Hysteresis of the system can be also measured. It will be shown that the actuator response is linear only for the low-frequency region (in our case as much as approximately 10 kHz). Above that frequency range, higher harmonics appear and cannot be neglected to obtain real displacement. Finally, it will be shown that the use of higher harmonics in calibration or detection schemes (that rely on the linearity of the response) must be validated, and this technique has proved adequate for that purpose.

© 2002 Optical Society of America

Full Article  |  PDF Article
More Like This
SIM PlanetQuest white-light fringe modeling: picometer accuracy calibration and estimation algorithms

Chengxing Zhai, Jeffrey Yu, Mike Shao, Renaud Goullioud, Mark Milman, and Tsae-Pyng Shen
Appl. Opt. 48(5) 847-861 (2009)

Wide dynamic range homodyne interferometry method and its application for piezoactuator displacement measurements

José Henrique Galeti, Paula Lalucci Berton, Cláudio Kitano, Ricardo Tokio Higuti, Ronny Calixto Carbonari, and Emílio Carlos Nelli Silva
Appl. Opt. 52(28) 6919-6930 (2013)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (4)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (6)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved