Abstract
A multispecies near-infrared diode laser spectrometer has been constructed for measurements of carbon monoxide, carbon dioxide, and methane directly in the exhaust of a static internal combustion engine. A wavelength modulation-division multiplexing scheme was implemented for the two distributed feedback diode lasers. Gas concentration variations were observed for changes in operating conditions such as increasing and decreasing the throttle, adjusting the air–fuel ratio, and engine start-up.
© 2007 Optical Society of America
Full Article | PDF ArticleMore Like This
Thomas N. Anderson, Robert P. Lucht, Soyuz Priyadarsan, Kalyan Annamalai, and Jerald A. Caton
Appl. Opt. 46(19) 3946-3957 (2007)
Michael Cundy, Torsten Schucht, Olaf Thiele, and Volker Sick
Appl. Opt. 48(4) B94-B104 (2009)
Jian Wang, Mikhail Maiorov, Douglas S. Baer, Dmitri Z. Garbuzov, John C. Connolly, and Ronald K. Hanson
Appl. Opt. 39(30) 5579-5589 (2000)