Abstract

The level of internal stray radiation is an important criterion to evaluate the performance of a thermal infrared spectrometer. In this study, a novel method is proposed and evaluated to measure the internal stray radiation of a thermal infrared spectrometer based on temperature variation. The proposed method was used to measure the internal stray radiation values of an existing instrument. First, two output gray value curves were constructed for a single spectral channel in a cryogenic detector at two different spectrometer temperatures based on radiometric calibration measurements. Subsequently, the gray value and radiation flux of the internal stray radiation of the spectrometer were calculated. In addition, the internal stray radiation data measured at different spectral channels and different integration times were used to verify and evaluate the proposed method. Results show that the proposed method is valid, and the standard deviations of the various internal radiation values of the tested spectral channels and the various integration times are 3.47% and 1.46%, respectively. The proposed method is adaptable, flexible, and efficient.

© 2019 Optical Society of America

Full Article  |  PDF Article
More Like This
Internal stray radiation measurement for cryogenic infrared imaging systems using a spherical mirror

Qijie Tian, Songtao Chang, Fengyun He, Zhou Li, and Yanfeng Qiao
Appl. Opt. 56(17) 4918-4925 (2017)

Analytical method for calculating internal stray radiation from an IR spectrometer based on the view factor

Zhi-Nan Zhang, Li-Bo Li, Bing-Liang Hu, Peng-Chong Wang, Ying Yang, Shan-Liang Ke, Shuang Wang, and Si-Yuan Li
Appl. Opt. 62(3) 725-734 (2023)

Analysis and correction of stray thermal radiation in infrared optical systems including an experimental case study

Zhi-Hui Yang, Yong-Hui Ma, Ju-Guang Guo, Wei-Wei Jiang, and Ai-Hui Geng
Appl. Opt. 58(13) 3582-3588 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (10)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (3)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (23)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved