Simulation technique enabling calibration-free frequency-modulation spectroscopy measurements of gas conditions and lineshapes with modulation frequencies spanning kHz to GHz

Abstract

A simulation technique enabling calibration-free measurements of gas properties (e.g., temperature, mole fraction) and lineshapes via wavelength- or frequency-modulation spectroscopy (WMS or FMS) is presented. Unlike previously developed models, this simulation technique accurately accounts for (1) absorption and dispersion physics and (2) variations in the WMS/FMS harmonic signals, which can result from intensity tuning induced by scanning the laser’s carrier frequency [e.g., via injection-current tuning of tunable diode lasers (TDLs)]. As a result, this approach is applicable to both WMS and FMS experiments employing a wide variety of light sources and any modulation frequency [typically kilohertz (kHz) to gigahertz (GHz)]. The accuracy of the simulation technique is validated via comparison with (1) simulated signals produced by established WMS and FMS models under conditions where they are accurate and (2) experimental data acquired under conditions where existing models are inaccurate. Under conditions where existing WMS and FMS models are accurate, this simulation technique yields nearly identical (within 0.1%) results. For experimental validation, the wavelength of a TDL emitting near 1392 nm was scanned across a single absorption line of $ {{\rm H}_2}{\rm O} $ with a half-width at half-maximum of 350 MHz while frequency modulation was performed at 100 MHz. The best-fit first-harmonic ($ 1f $) signal produced by this simulation technique agrees within 1.6% of the measured $ 1f $ signal, and the $ {{\rm H}_2}{\rm O} $ mole fraction and transition collisional width corresponding to the best-fit $ 1f $ spectrum agree within 1% of expected values.

© 2020 Optical Society of America

Full Article  |  PDF Article

Corrections

10 February 2020: Corrections were made to Eq. (13) and to Fig. 6.


More Like This
Fitting of calibration-free scanned-wavelength-modulation spectroscopy spectra for determination of gas properties and absorption lineshapes

Christopher S. Goldenstein, Christopher L. Strand, Ian A. Schultz, Kai Sun, Jay B. Jeffries, and Ronald K. Hanson
Appl. Opt. 53(3) 356-367 (2014)

Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments

Gregory B. Rieker, Jay B. Jeffries, and Ronald K. Hanson
Appl. Opt. 48(29) 5546-5560 (2009)

Real-time, in situ measurement of H2O generated during in situ combustion tests using 1f-normalized wavelength modulation spectroscopy with second harmonic detection

Juan E. Duque, Manuel Jaramillo, Sebastian López, Pedro Torres, and Alejandro Molina
Appl. Opt. 62(1) 108-116 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (17)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved