Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

In-flight radiometric and polarimetric calibration of the Directional Polarimetric Camera onboard the GaoFen-5 satellite over the ocean

Not Accessible

Your library or personal account may give you access

Abstract

The Directional Polarimetric Camera (DPC) is the first Chinese multi-angle polarized Earth observation satellite sensor, which was successfully launched on 9 May 2018, onboard the GaoFen-5 satellite in the Chinese High-Resolution Earth Observation Program. The DPC’s observation is one of the most important space-borne multi-spectral, multi-angular polarimetric measurements of the global Earth-atmosphere system at the present stage. Although rigorous radiometric calibration had been performed for the DPC before launch, its in-flight performance may change because of the process of launch, harsh environment of space, and aging of the sensor. Due to the absence of the onboard calibration system, vicarious calibration methods are necessary for the DPC’s in-flight performance monitoring and calibration. In this paper, we adapted the Rayleigh absolute calibration method, the sun glint inter-band calibration method, and the sun glint polarization calibration method to the DPC sensor. First, the calibration errors of these three methods caused by ancillary data uncertainties (e.g.,  aerosol, chlorophyll concentration, absorption gases amount, and wind speed) were analyzed in detail. The error budgets show that the aerosol parameters (optical thickness and aerosol model) are some of the critical factors affecting both the radiometric and polarimetric calibration accuracies for the Rayleigh and sun glint methods. The DPC radiometric and polarimetric in-flight calibration during its commissioning phase was then implemented. The absolute coefficients of short spectral bands (443, 490, 565, and 670 nm) were calibrated by the well-characterized Rayleigh scattering signal over the ocean. Using the 565 nm band as a reference band, the Rayleigh absolute calibration was then transferred to other bands (443, 490, 670, and 865 nm) through inter-band calibration using the specular reflection of the sun over the ocean. The polarization measurements of the DPC at polarized bands (490, 670, and 865 nm) were calibrated with the polarized reflection of the sun glint over ocean. The preliminary results show that the radiometric sensitivity of the DPC changed very little after launch at the four visible bands. The absolute calibration coefficient differences from pre-flight calibration are smaller than 0.5% at the 443 and 670 nm bands, while they are within ${\rm{\pm 2}}\%$ at the 490 and 565 nm bands. However, a large deviation at 865 nm band of about 9% from pre-flight calibration was indicated by the sun glint inter-band calibration. The degree of linear polarization measurement of the DPC is validated with high accuracy of about 0.02 at the 865 nm band, while the deviation at 490 and 670 nm bands are relatively larger, reaching 0.04. The DPC/GaoFen-5 shows a good in-flight performance of radiometric measurement and generally reliable polarimetric measurement after launch.

© 2021 Optical Society of America

Full Article  |  PDF Article
More Like This
Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera

Chan Huang, Guangfeng Xiang, Yuyang Chang, Lin Han, Miaomiao Zhang, Shuang Li, Bihai Tu, Binghuan Meng, and Jin Hong
Opt. Express 28(9) 13187-13215 (2020)

Polarization measurement accuracy analysis and improvement methods for the directional polarimetric camera

Chan Huang, Yuyang Chang, Guangfeng Xiang, Lin Han, Feinan Chen, Donggen Luo, Shuang Li, Liang Sun, Bihai Tu, Binghuan Meng, and Jin Hong
Opt. Express 28(26) 38638-38666 (2020)

PARASOL in-flight calibration and performance

Bertrand Fougnie, Guillaume Bracco, Bruno Lafrance, Caroline Ruffel, Olivier Hagolle, and Claire Tinel
Appl. Opt. 46(22) 5435-5451 (2007)

Data Availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (11)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (5)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (14)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.