Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Theoretical model considering optimal ranging performance and energy efficiency for photon-counting lidars with multiple detectors

Not Accessible

Your library or personal account may give you access

Abstract

With an orbital speed of several kilometers per second, space-borne photon-counting lidars can only perform several to a few tens of measurements on the same target. The ranging uncertainty can exceed tens of centimeters with a pulse width of several nanoseconds and has a great impact on the total ranging error. When multiple photons are recorded (using multiple detectors) in a single laser shot, the ranging uncertainty can be effectively suppressed by the average method. Higher signal levels (receiving more photons) introduce a better ranging uncertainty, but a worse ranging bias is caused by the dead time effect of photon-counting detectors. In this study, a theoretical ranging performance model is proposed to address that question: What signal levels and how many detectors are the optimum selection to achieve a better ranging performance? A photon-counting lidar system with four photomultiplier tubes is used to verify the proposed ranging performance model. Experiments are conducted under nine sets of different signal levels, and the ranging performance of experiment results agree well with the theoretical predictions. The average residual error is 0.31 cm and all error ratios are less than 10%. The energy efficiency and ranging uncertainty are further quantitatively analyzed. When multiple detectors are employed, the total ranging error (i.e., the root sum square of the ranging bias and ranging uncertainty) has the minimum value. For a space-borne photon-counting lidar, the expected signal photon number in each detector is recommended as ${0.5}\sim{1}$ (wasting a small part of the received energy). With a ${4} \times {4}$ detector array and a received pulse width of 1.5 ns, the total ranging error can reach approximately 5 cm when the expected signal photon number is close to 10. This theoretical model is essential in estimating the ranging performance for a give photon-counting lidar and in optimizing the design of lidar system parameters.

© 2021 Optical Society of America

Full Article  |  PDF Article
More Like This
Theoretical ranging performance model and range walk error correction for photon-counting lidars with multiple detectors

Yue Ma, Song Li, Wenhao Zhang, Zhiyu Zhang, Rui Liu, and Xiao Hua Wang
Opt. Express 26(12) 15924-15934 (2018)

Ranging performance model considering the pulse pileup effect for PMT-based photon-counting lidars

Zhiyu Zhang, Yue Ma, Song Li, Pufan Zhao, Yuyan Xiang, Xinyuan Liu, and Wenhao Zhang
Opt. Express 28(9) 13586-13600 (2020)

Ranging performance models based on negative-binomial (NB) distribution for photon-counting lidars

Song Li, Zhiyu Zhang, Yue Ma, Haomin Zeng, Pufan Zhao, and Wenhao Zhang
Opt. Express 27(12) A861-A877 (2019)

Data Availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (13)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (16)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved