Abstract
Among 3D measurement approaches, multi-frequency phase-shifting structured light has advantages such as high resolution and high sampling rate owing to its point-to-point calculation method. However, there is always phase jump in the measurement process, which greatly reduces measurement accuracy. This paper proposes an error self-correction method for phase jump based on the multi-frequency heterodyne approach. The method uses redundant measurement data to implement self-correction and does not require additional data acquisition steps. We perform both simulations and experiments using the proposed error self-correction method and the classical heterodyne approach to compare the results. The experiment results verify both the accuracy and suitability of the proposed method.
© 2021 Optical Society of America
Full Article | PDF ArticleMore Like This
Zhoujie Wu, Wenbo Guo, Lilian Lu, and Qican Zhang
Opt. Express 29(17) 27181-27192 (2021)
Namyoon Kim and Soonyang Kwon
Appl. Opt. 60(30) 9311-9318 (2021)
Yuk-Ching Leung and Lilong Cai
Appl. Opt. 61(1) 208-222 (2022)