Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Improved calibration method of a four-quadrant detector based on Bayesian theory in a laser auto-collimation measurement system

Not Accessible

Your library or personal account may give you access

Abstract

Reliable and accurate calibration for a four-quadrant detector (QD) is a prerequisite for high-accuracy laser auto-collimation measurements. However, the calibration accuracy is limited largely by the non-linearity of QD, especially for large-range detection. To address this issue, an improved calibration method of QD based on Bayesian theory in laser auto-collimation measurement is proposed in this paper. First, the non-linearity problem of QD is analyzed, and for accurate calibration of QD, a high-precision identification model based on Bayesian theory is presented. An analytical expression between the output signal of QD and the position of the laser spot is established, and then a calibration system with laser drift compensation to avoid influences from the laser source as a datum is constructed. A series of experiments is conducted to verify the performance of the improved calibration method. The results reveal that the improved method can effectively enhance the calibration accuracy of QD and reduce the residuals in root mean square error by 86% compared to the 15-order polynomial fitting over a detection range of ${{\pm 1}}\;{\rm{mm}}$. The comparison experiments also demonstrate that the proposed calibration method has advantages over the conventional method in terms of accuracy and robustness.

© 2022 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Neural-network-based method for improving measurement accuracy of four-quadrant detectors

Zhaobing Qiu, Weihao Jia, Xiao Ma, Bohao Zou, and Liyu Lin
Appl. Opt. 61(9) F9-F14 (2022)

Improved measurement accuracy of spot position on an InGaAs quadrant detector

Jiabin Wu, Yunshan Chen, Shijie Gao, Yimang Li, and Zhiyong Wu
Appl. Opt. 54(27) 8049-8054 (2015)

Improved algorithm for expanding the measurement linear range of a four-quadrant detector

Jun Zhang, Weixian Qian, Guohua Gu, Chen Mao, Kan Ren, Chunhong Wu, Xiaoyu Peng, and Qian Chen
Appl. Opt. 58(28) 7741-7748 (2019)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (9)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (14)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.