Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Pointing-error correction of optical communication terminals on motion platforms using a parameter model and kernel weight function estimation

Not Accessible

Your library or personal account may give you access

Abstract

Optical communication terminals (OCTs) with high pointing accuracy on motion platforms are highly important for establishing a global communication network. The pointing accuracy of such OCTs is seriously affected by linear and nonlinear errors generated by various sources. A method based on a parameter model and kernel weight function estimation (KWFE) is proposed to correct the pointing errors of an OCT on a motion platform. Initially, a parameter model, which has a physical meaning, is established to reduce the linear pointing errors. Then, the nonlinear pointing errors are corrected using the proposed KWFE method. Tracking star experiments are conducted to verify the efficiency of the proposed method. The parameter model reduces the initial pointing error associated with the stars used for calibration from 1311.5 µrad to 87.0 µrad. After applying parameter model correction, the KWFE method is applied to further reduce the modified pointing error associated with the stars used for calibration from 87.0 µrad to 70.5 µrad. Additionally, based on the parameter model, the KWFE method reduces the actual open-loop pointing error associated with the target stars from 93.7 µrad to 73.3 µrad. The sequential correction using the parameter model and KWFE can gradually and effectively improve the pointing accuracy of an OCT on a motion platform.

© 2023 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Modeling and correction for the optical axis pointing error of an airborne electro-optical platform

Cheng Xu, Wei Han, Dongzhen Wang, Daqing Huang, and Pengfei Yuan
Appl. Opt. 58(23) 6455-6463 (2019)

Modeling and digital calibration for the mirror normal pointing error of the 2D scanning reflector

Hongda Zhao, Shunhe Li, Tao Jiang, Yuan Hong, and Zhicheng Ma
Appl. Opt. 62(10) 2642-2650 (2023)

Analysis of scanning systematic errors for airborne laser bathymetry

Libin Du, Tong Cui, Xiangqian Meng, Yibo Yuan, Liwei Wang, Zhiwei Shang, Hao Chen, and Hongzhi Huang
Appl. Opt. 62(26) 6939-6951 (2023)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (10)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (18)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.