Optimization of Sample Preparation Using Glass Slides for Spectral Pathology

Open Access Open Access

Abstract

The clinical translation of Fourier transform infrared (FT-IR) microspectroscopy in pathology will require bringing this technique as close as possible to standard practice in pathology departments. An important step is sample preparation for both FT-IR microspectroscopy and pathology. This should entail minimal disruption of standard clinical practice while achieving good quality FT-IR spectral data. In fact, the recently described possibility of obtaining FT-IR spectra of cells placed on glass substrates brings FT-IR microspectroscopy closer to a clinical application. We have now furthered this work in order to identify two different types of lung cancer cells placed on glass coverslips. Two types of sample preparation which are widely used in pathology, cytospin and smear, have been used. Samples were fixed with either methanol, used in pathology, or formalin (4% paraformaldehyde) used widely in spectroscopy. Fixation with methanol (alcohol-based fixative) removed lipids from cells causing a decrease in intensity of the peaks at 2850 cm−1 and 2920 cm−1. Nevertheless, we show for the first time that using either type of sample preparation and fixation on thin glass coverslips allowed to differentiate between two different types of lung cancer cells using either the lipid region or the fingerprint region ranging from 1800 cm−1 to 1350 cm−1. We believe that formalin-fixed cytospin samples would be preferred to study cells on thin coverslips using FT-IR microspectroscopy. This work presents a clear indication for future advances in clinical assessment of samples within pathology units to gain a deeper understanding of cells/tissues under investigation.

© 2020 The Author(s)

PDF Article
More Like This
Mueller matrix imaging of pathological slides with plastic coverslips

Tongyu Huang, Yue Yao, Haojie Pei, Zheng Hu, Fengdi Zhang, Jing Wang, Guangyin Yu, Chuqiang Huang, Huanyu Liu, Lili Tao, and Hui Ma
Opt. Express 31(10) 15682-15696 (2023)

Detecting brain tumor in pathological slides using hyperspectral imaging

Samuel Ortega, Himar Fabelo, Rafael Camacho, María de la Luz Plaza, Gustavo M. Callicó, and Roberto Sarmiento
Biomed. Opt. Express 9(2) 818-831 (2018)

Distinction of cervical cancer biopsies by use of infrared microspectroscopy and probabilistic neural networks

A. Podshyvalov, R. K. Sahu, S. Mark, K. Kantarovich, H. Guterman, J. Goldstein, R. Jagannathan, S. Argov, and S. Mordechai
Appl. Opt. 44(18) 3725-3734 (2005)

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.