Simultaneous multielement atomic absorption spectroscopy has not become a common laboratory workhorse for elemental analyses despite recent advances in instrumentation. Two major obstacles preventing its implementation are the sometimes severe matrix interferences which occur in some pulsed atomizers and the limited working range of atomic absorption spectroscopy compared to the wide linear dynamic range of inductively coupled plasma-atomic emission spectroscopy. Use of a constant temperature furnace in conjuction with techniques such as peak width at fixed height, random dilutions with element rationing, and monitoring two or more wavelengths of different sensitivities of an element are effective methods for eliminating or reducing these obstacles. Determination of trace zinc in unweighed samples of reagent grade CdCl<sub>2</sub>·2.5H<sub>2</sub>O and the determination of lead in unknown volumes of blood using hemoglobin iron as the internal standard are examples of analyses performed on the dual channel monochromator used in this work. Problems in selecting appropriate compromise conditions of atomization are exemplified in work done on solid samples. Although full recoveries of Zn and Cd were obtained at 1800 K in biological samples, low recoveries for Zn were obtained in NBS coal fly ash at this temperature. Atomization at 2100 K was necessary to restore full recovery.

PDF Article
More Like This
Hot Tube Atomic Absorption Spectrochemistry

Ray Woodriff and Ronald W. Stone
Appl. Opt. 7(7) 1337-1339 (1968)

Laser-induced breakdown spectroscopy at high temperatures in industrial boilers and furnaces

Linda G. Blevins, Christopher R. Shaddix, Shane M. Sickafoose, and Peter M. Walsh
Appl. Opt. 42(30) 6107-6118 (2003)

Accurate wavelength calibration in the near-infrared for multielement analysis without the need for reference spectra

George Asimellis, Aggelos Giannoudakos, and Michael Kompitsas
Appl. Opt. 45(35) 8855-8862 (2006)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.