Abstract
We have developed procedures to determine 12 trace elements, Al, As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, and V, in natural water using the stabilized temperature platform furnace. Suitable matrix modifiers were tested. Confirmation of the techniques was obtained by recovery experiments at four different concentration levels. Only simple aqueous standards were required and the method of additions was not used. A simple recovery experiment was satisfactory confirmation of freedom from chemical interferences. The detection limits in the natural waters were less than 1 μg/liter, closer to 0.1 μg/liter for most of the elements. The precision was 10 to 15%. The work did not require clean-room facilities.
PDF Article
More Like This
Sensitive determinations of Cu, Pb, Cd, and Cr elements in aqueous solutions using chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy
X. Y. Yang, Z. Q. Hao, C. M. Li, J. M. Li, R. X. Yi, M. Shen, K. H. Li, L. B. Guo, X. Y. Li, Y. F. Lu, and X. Y. Zeng
Opt. Express 24(12) 13410-13417 (2016)
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator
or
Login to access Optica Member Subscription