An Experimental Study of the Precision of Fluorescence Measurements

Not Accessible

Your library or personal account may give you access

Abstract

The precision of fluorescence measurements by the SLM 22 fluorometer was calculated with the use of fluorescein solutions of varying concentrations. Relative standard deviations for 10 replicate fluorescence measurements, each integrated over five seconds, are not observably affected by the changing of bandpasses from 1 to 8 nm, by the changing of cell orientation, or by fluorescein concentration at levels of 1.0 × 10<sup>−9</sup>M and above. Fluctuations in source intensity are shown to be the primary source of noise. Statistical fluctuations in photon and photoelectron flux do not seem to be a significant source of variability. Because of this, the precision of single-channel intensity measurements is poorer than for intensity measurements ratioed directly to source intensity. However, the precisions of the ratio of fluorescence intensities measured by dual detectors on opposite sides of the cell were often found to be better than for intensity measurements ratioed to the source. It is hypothesized that this is observed because the measurements of source intensity and fluorescence are not identically affected by fluctuations in the source. At fluorescein concentrations in the 10<sup>−9</sup>M range and above, percent RSDs for single channel measurements typically fall in the range of 0.2% to 0.5%, although occasionally larger values are observed. The percent RSDs for the ratio of simultaneous fluorescence measurements are typically in the range of 0.1 to 0.2% at higher concentrations.

PDF Article
More Like This
Two-line atomic fluorescence temperature measurement in flames: an experimental study

Richard G. Joklik and John W. Daily
Appl. Opt. 21(22) 4158-4162 (1982)

Precision analysis for standard deviation measurements of immobile single fluorescent molecule images

Michael C. DeSantis, Shawn H. DeCenzo, Je-Luen Li, and Y. M. Wang
Opt. Express 18(7) 6563-6576 (2010)

Precise intensity correlation measurement for atomic resonance fluorescence from optical molasses

Kazuyuki Nakayama, Yutaka Yoshikawa, Hisatoshi Matsumoto, Yoshio Torii, and Takahiro Kuga
Opt. Express 18(7) 6604-6612 (2010)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.