Simultaneous Orthogonal Drug Detection Using Fully Integrated Gas Chromatography with Fourier Transform Infrared Detection and Mass Spectrometric Detection

Not Accessible

Your library or personal account may give you access

Abstract

Analytes that co-elute and yield nearly identical electron ionization (EI) mass spectra, as well as analytes that yield non-specific EI fragmentation patterns, have been identified using fully integrated gas chromatography with direct deposit Fourier transform infrared detection and mass spectrometric detection (GC/FT-IR/MS). While the IR detector proved to be more selective for identifying analytes such as synthetic cannabinoids and weight loss drugs, it was limited by a relatively high detection limit of 8.4 parts per million (ppm) for non-targeted identification of sibutramine based on a single injection but was reduced to 840 parts per billion (ppb) for targeted identification of sibutramine by redepositing ten injections along the same track. The MS detector was less selective for identifying these analytes but yielded non-targeted and targeted detection limits of approximately 84 ppb and 8.4 ppb, respectively, which corresponded to a 100-fold advantage compared to the IR detector. Overall, the results of this study demonstrate that the advantages of each detector compensate for the limitations of the other, which allows a wider range of analytes and concentrations to be examined using a fully integrated GC/FT-IR/MS instrument compared to what can be examined using GC/IR or GC/MS independently. Not only does this approach reduce consumption of laboratory resources and time, it provides IR and MS information on the same sample, which is important for forensic analyses that require data from two or more orthogonal techniques to make an identification.

© 2016 The Author(s)

PDF Article
More Like This
Nonlinear interferometer for Fourier-transform mid-infrared gas spectroscopy using near-infrared detection

Chiara Lindner, Jachin Kunz, Simon J. Herr, Sebastian Wolf, Jens Kießling, and Frank Kühnemann
Opt. Express 29(3) 4035-4047 (2021)

Ultraviolet laser microplasma–gas chromatography detector: detection of species-specific fragment emission

Randy J. Locke, Jeffrey B. Morris, Brad E. Forch, and Andrzej W. Miziolek
Appl. Opt. 29(33) 4987-4992 (1990)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.