Pressure-Dependent Detection of Carbon Monoxide Employing Wavelength Modulation Spectroscopy Using a Herriott-Type Cell

Not Accessible

Your library or personal account may give you access

Abstract

Wavelength modulation spectroscopy (WMS) combined with a multipass absorption cell has been used to measure a weak absorption line of carbon monoxide (CO) at 1.578 µm. A 0.95m Herriott-type cell provides an effective absorption path length of 55.1 m. The WMS signals from the first and second harmonic output of a lock-in amplifier (WMS-1f and 2f, respectively) agree with the Beer–Lambert law, especially at low concentrations. After boxcar averaging, the minimum detection limit achieved is 4.3 ppm for a measurement time of 0.125 s. The corresponding normalized detection limit is 84 ppm m Hz–1/2. If the integrated time is increased to 88 s, the minimum detectable limit of CO can reach to 0.29 ppm based on an Allan variation analysis. The pressure-dependent relationship is validated after accounting for the pressure factor in data processing. Finally, a linear correlation between the WMS-2f amplitudes and gas concentrations is obtained at concentration ratios less than 15.5%, and the accuracy is better than 92% at total pressure less than 62.7 Torr.

© 2016 The Author(s)

PDF Article
More Like This
Quantum cascade laser absorption sensor for carbon monoxide in high-pressure gases using wavelength modulation spectroscopy

R. M. Spearrin, C. S. Goldenstein, J. B. Jeffries, and R. K. Hanson
Appl. Opt. 53(9) 1938-1946 (2014)

Double-range near-infrared acetylene detection using a dual spot-ring Herriott cell (DSR-HC)

Ming Dong, Chuantao Zheng, Dan Yao, Guoqiang Zhong, Shuzhuo Miao, Weilin Ye, Yiding Wang, and Frank K. Tittel
Opt. Express 26(9) 12081-12091 (2018)

Pressure-dependent sensitivity of a single-pass methane detection system using a continuous-wave distributed feedback laser at 3270  nm

Seyed Ghasem Razavipour, James A. Gupta, Graeme Sabiston, Nicaulas Sabourin, Andrew Bezinger, Jean Lapointe, and Daniel Poitras
Appl. Opt. 58(25) 6906-6911 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.