Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Near-Infrared Diffuse Reflectance Measurement Method Based on Temperature-Insensitive Radial Distance

Not Accessible

Your library or personal account may give you access

Abstract

The variation of temperature is one of the main interference factors that affect the detection accuracy of near-infrared (NIR) diffuse reflectance. In this paper, a measurement method based on temperature-insensitive radial distance was proposed, and its feasibility and effectiveness were verified in Intralipid solutions. First, the possibility of temperature-insensitive radial distance was deduced based on the analytic solution of the steady-state diffusion equation in an infinite media, and the temperature-insensitive radial distances of 3% Intralipid solution in the wavelength range of 1000–1600 nm was calculated. Second, a detection system was designed to measure the diffuse reflectance of 3% Intralipid solutions at multiple radial distances with different glucose concentration (0–100 mM) and different temperatures (35–40°C). Both theoretical calculations and experimental results demonstrated the existence of temperature-insensitive radial distances in the range of 1000–1340 nm and 1440–1600 nm, and the distances were hardly affected by glucose variations. Finally, the glucose information extracted from the diffuse reflectance of Intralipid solutions at different radial distances under random temperature variations and constant temperature were compared. The result showed that the correlation between the glucose concentration and the diffuse reflectance obtained at the temperature-insensitive radial distance was significantly better than that of other radial distances, which was almost close to the situation of constant temperature. Therefore, the measurement method based on temperature-insensitive radial distance can effectively reduce the influence of temperature variations on NIR diffuse reflectance, and it is expected to improve the accuracy of diffuse reflectance in human body components detection and industrial field analysis.

© 2018 The Author(s)

PDF Article
More Like This
Temperature measurements of turbid aqueous solutions using near-infrared spectroscopy

Naoto Kakuta, Hidenobu Arimoto, Hideyuki Momoki, Fuguo Li, and Yukio Yamada
Appl. Opt. 47(13) 2227-2233 (2008)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.