Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Raman Spectroscopic Detection and Quantification of Macro- and Microhematuria in Human Urine

Not Accessible

Your library or personal account may give you access

Abstract

Hematuria refers to the presence of blood in urine. Even in small amounts, it may be indicative of disease, ranging from urinary tract infection to cancer. Here, Raman spectroscopy was used to detect and quantify macro- and microhematuria in human urine samples. Anticoagulated whole blood was mixed with freshly collected urine to achieve concentrations of 0, 0.25, 0.5, 1, 2, 6, 10, and 20% blood/urine (v/v). Raman spectra were obtained at 785 nm and data analyzed using chemometric methods and statistical tests with the Rametrix toolboxes for Matlab. Goldindec and iterative smoothing splines with root error adjustment (ISREA) baselining algorithms were used in processing and normalization of Raman spectra. Rametrix was used to apply principal component analysis (PCA), develop discriminate analysis of principal component (DAPC) models, and to validate these models using external leave-one-out cross-validation (LOOCV). Discriminate analysis of principal component models were capable of detecting various levels of microhematuria in unknown urine samples, with prediction accuracies of 91% (using Goldindec spectral baselining) and 94% (using ISREA baselining). Partial least squares regression (PLSR) was then used to estimate/quantify the amount of blood (v/v) in a urine sample, based on its Raman spectrum. Comparing actual and predicted (from Raman spectral computations) hematuria levels, a coefficient of determination (R2) of 0.91 was obtained over all hematuria levels (0–20% v/v), and an R2 of 0.92 was obtained for microhematuria (0–1% v/v) specifically. Overall, the results of this preliminary study suggest that Raman spectroscopy and chemometric analyses can be used to detect and quantify macro- and microhematuria in unprocessed, clinically relevant urine specimens.

© 2022 The Author(s)

PDF Article
More Like This
Rapid and label-free urine test based on surface-enhanced Raman spectroscopy for the non-invasive detection of colorectal cancer at different stages

Jinyong Lin, Zongwei Huang, Xueliang Lin, Qiong Wu, Kerun Quan, Yanming Cheng, Mingzhi Zheng, Jiaying Xu, Yitao Dai, Hejin Qiu, Duo Lin, and Shangyuan Feng
Biomed. Opt. Express 11(12) 7109-7119 (2020)

Detection of hemoglobin in blood and urine glucose level samples using a graphene-coated SPR based biosensor

Shahriar Mostufa, Alok Kumar Paul, and Kisalaya Chakrabarti
OSA Continuum 4(8) 2164-2176 (2021)

Supplementary Material (3)

NameDescription
Supplement 1       sj-xlsx-1-asp-10.1177_00037028211060853 – Supplemental Material for Raman Spectroscopic Detection and Quantification of Macro- and Microhematuria in Human Urine
Supplement 2       sj-xlsx-2-asp-10.1177_00037028211060853 – Supplemental Material for Raman Spectroscopic Detection and Quantification of Macro- and Microhematuria in Human Urine
Supplement 3       sj-pdf-3-asp-10.1177_00037028211060853 – Supplemental Material for Raman Spectroscopic Detection and Quantification of Macro- and Microhematuria in Human Urine

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.