Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 76,
  • Issue 3,
  • pp. 318-330
  • (2022)

Circular Dichroism Spectral Similarity Plots to Extend Validation and Correction to All Measured Wavelengths

Not Accessible

Your library or personal account may give you access

Abstract

Interlaboratory comparisons of circular dichroism (CD) spectra are useful for developing confidence in the measurements associated with optically active molecules. These measurements also help define the higher-order (secondary and tertiary) structure of biopolymers. Unfortunately, the extent of the validity of these measurements has been unclear. In this work, a method is described to extend CD validation over the entire observed wavelength range using what will be called spectral similarity plots. The method involves plotting, wavelength by wavelength, all measured spectral intensities of a sample at one concentration against the intensity values of the same material at a different concentration or pathlength. These spectral similarity plots validate the instrument in terms of spectral shape and whether the shape is shifted in intensity and/or in wavelength. This comparison tests the linearity of instrument's signal, the balance of its left and right polarizations, its wavelengths, and its spectral intensity scales. When the process is applied to materials with accepted and archived intensity values, the method can be linked to older single-wavelength and double-wavelength calibration techniques. Further, spectral similarity testing of CD spectra from samples with different concentrations run in different labs suggests that improved interlaboratory validation of CD data is possible. Since a database of archival CD measurements is available online, spectral similarity comparisons could possibly provide the ability to compare linearity, polarization balance, wavelength, and spectral intensity between all current CD instruments. If the preliminary results published here prove robust and transferable, then comparisons of full-wavelength range spectra to archived data using spectral similarity plots should become part of the standard process to validate and calibrate the performance of CD instruments.

© 2022 The Author(s)

PDF Article
More Like This
Device for real-time measuring of circular dichroism at a specific wavelength

Hakob Margaryan, Nelson Tabirian, Tigran Sargsyan, Petros Gasparyan, Nune Hakobyan, Valeri Abrahamyan, Hakob Chilingaryan, and David Pokhsraryan
J. Opt. Soc. Am. B 36(5) D66-D69 (2019)

Snapshot circular dichroism measurements

Oriol Arteaga, Zoubir El-Hachemi, and Razvigor Ossikovski
Opt. Express 27(5) 6746-6756 (2019)

Measuring the dynamics of circular dichroism in a pump-probe experiment with a Babinet-Soleil Compensator

Claire Niezborala and François Hache
J. Opt. Soc. Am. B 23(11) 2418-2424 (2006)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.