Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Performance Improvement of Handheld Raman Spectrometer for Mixture Components Identification Using Fuzzy Membership and Sparse Non-Negative Least Squares

Not Accessible

Your library or personal account may give you access

Abstract

Due to the advantages of low price and convenience for end-users to conduct field-based, in-situ analysis, handheld Raman spectrometers are widely used in the identification of mixture components. However, the spectra collected by handheld Raman spectrometer usually have serious peak overlapping and spectral distortion, resulting in difficulties in component identification in the mixture. A novel method for mixture components identification based on the handheld Raman spectrometer was proposed in this study. The wavelet transform and Voight curve fitting method were used to extract the feature parameters from each Raman spectral peak, including Raman shift, maximum intensity, and full width at half-maximum (FWHM), and the similarities between the mixture and each substance in the database were calculated by fuzzy membership function based on extracted feature parameters. Then, the possible substances in the mixture were preliminarily screened out as candidates according to the similarity. Finally, the Raman spectra of these candidates were used to fit the spectra of the mixture, and the fitting coefficients obtained by sparse non-negative least squares algorithm were employed to further determine the suspected substance in the mixture. The Raman spectra of 190 liquid mixture samples and 158 powder mixture samples were collected using a handheld Raman spectrometer and these spectra were used to validate the identification performance of the proposed method. The proposed method could achieve good identification accuracy for different mixture samples. It shows that the proposed method is an effective way for the component identification in mixture by using a handheld Raman spectrometer.

© 2022 The Author(s)

PDF Article
More Like This
Baseline correction for Raman spectra using a spectral estimation-based asymmetrically reweighted penalized least squares method

Yixin Guo, Weiqi Jin, Weilin Wang, Yuqing He, and Su Qiu
Appl. Opt. 62(18) 4766-4776 (2023)

Component spectra extraction from terahertz measurements of unknown mixtures

Xian Li, D. B. Hou, P. J. Huang, J. H. Cai, and G. X. Zhang
Appl. Opt. 54(30) 8925-8934 (2015)

Applications of the non-negative least-squares deconvolution method to analyze energy-dispersive x-ray fluorescence spectra

Wei Zhao, Xianyu Ai, Wuyun Xiao, Ye Chen, Jinglun Li, Hui Zhao, and Wenzhuo Chen
Appl. Opt. 62(20) 5556-5564 (2023)

Supplementary Material (1)

NameDescription
Supplement 1       sj-pdf-1-asp-10.1177_00037028221080205 – Supplemental Material for Performance Improvement of Handheld Raman Spectrometer for Mixture Components Identification Using Fuzzy Membership and Sparse Non-Negative Least Squares

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.