Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of the Optical Society of Korea
  • Vol. 19,
  • Issue 4,
  • pp. 403-408
  • (2015)

Simulation of the Through-Focus Modulation Transfer Functions According to the Change of Spherical Aberration in Pseudophakic Eyes

Open Access Open Access

Abstract

To evaluate the effects of spherical aberration (SA) correction on optical quality in pseudophakic eyes, we simulated the optical quality of the human eye by computation of the modulation transfer function (MTF). We reviewed the medical records of patients who underwent cataract surgery in Asan Medical Center, retrospectively. A Zywave aberrometer was used to measure optical aberrations at 1-12 postoperative months in patients with AR40e intraocular lens implants. The MTF was calculated for a 5 mm pupil from measured wavefront aberrations. The area under the MTF curve (aMTF) was analyzed and the maximal aMTF was calculated while changing the SA (<TEX>$-0.2{\sim}+0.2{\mu}m$</TEX>) and the defocus (-2.0 ~ +2.0 D). Sixty-four eyes in 51 patients were examined. The maximal aMTF was <TEX>$6.61{\pm}2.16$</TEX> at a defocus of <TEX>$-0.25{\pm}0.66D$</TEX> with innate SA, and <TEX>$7.64{\pm}2.63$</TEX> at a defocus of <TEX>$0.08{\pm}0.53D$</TEX> when the SA was 0 (full correction of SA). With full SA correction, the aMTF increased in 47 eyes (73.4%; Group 1) and decreased in 17 eyes (26.6%; Group 2). There were statistically significant differences in Z(3, -1) (vertical coma; P = 0.01) and Z(4, 4) (tetrafoil; P = 0.04) between the groups. The maximal aMTF was obtained at an SA of <TEX>$+0.01{\mu}m$</TEX> in Group 1 and an SA of <TEX>$+0.13{\mu}m$</TEX> in Group 2. Optical quality can be improved by full correction of SA in most pseudophakic eyes. However, residual SA might provide benefits in eyes with significant radially asymmetric aberrations.

© 2015 Optical Society of Korea

PDF Article
More Like This
Improvement of neural contrast sensitivity after long-term adaptation in pseudophakic eyes

Seung Pil Bang, Justin D. Aaker, Ramkumar Sabesan, and Geunyoung Yoon
Biomed. Opt. Express 13(9) 4528-4538 (2022)

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.