Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Instrument matrix of the four-detector photopolarimeter: physical meaning of its rows and columns and constraints on its elements

Not Accessible

Your library or personal account may give you access

Abstract

The four-detector photopolarimeter (FDP) is an arrangement of four photodetectors for measuring the state of polarization of light. The output current vector I of the FDP is related to the input Stokes vector S by I = AS, where A is the instrument matrix. The rows of A can be viewed as projection operators that determine the output currents of the detectors. This leads to the recognition of four special totally polarized input states, each of which maximizes the output of one detector. The associated four orthogonal states produce minimum signals. Because each detector is absorptive and its output is nonnegative, eight inequalities must be satisfied by the elements of A. For optically isotropic detectors, one element is identically zero and another can be made zero by an appropriate coordinate rotation. Three additional inequalities that are likely to apply are also stated. The columns of A have the following interesting meaning. The first column represents the normalized response of the FDP for incident unpolarized light or its average response to incident light polarized in any pair of orthogonal states. The second, third, and fourth columns represent the differential normalized responses of the FDP for incident light polarized in the following pairs of orthogonal states: (1) linear polarizations at 0 and 90° azimuths, (2) linear polarizations at 45° and 135° azimuths, and (3) the right and left circular polarizations, respectively. These are the same pairs of orthogonal states that are used in the phenomenological definitions of the Stokes parameters.

© 1990 Optical Society of America

Full Article  |  PDF Article
More Like This
Accurate calibration of the four-detector photopolarimeter with imperfect polarizing optical elements

R. M. A. Azzam and Ali G. Lopez
J. Opt. Soc. Am. A 6(10) 1513-1521 (1989)

General analysis and optimization of the four-detector photopolarimeter

R. M. A. Azzam, I. M. Elminyawi, and A. M. El-Saba
J. Opt. Soc. Am. A 5(5) 681-689 (1988)

Mueller-matrix measurement using the four-detector photopolarimeter

R. M. A. Azzam
Opt. Lett. 11(5) 270-272 (1986)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (38)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.