Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Measurement of contamination concentration using an adjustable image contrast method

Not Accessible

Your library or personal account may give you access

Abstract

The results of an investigation that focused on the development of an adjustable image contrast method are presented. The method was designed to solve the applied problem of measuring the concentration of contamination of recoverable scrap with cutting fluid to enhance the accuracy of visual inspection methods. The currently used control method is based on visual assessment of the degree of contamination of a sheet of paper after its contact with a sample of contaminated material. The proposed method entails the use of a standard image scanner for digitizing visual information in the form of oil imprints on the paper and its subsequent processing by adjusting the image contrast, which makes it possible to obtain quantitative information on the object under investigation. The principal parameters of oil imprint scanning and subsequent processing of the obtained images were determined during the course of the study. Equations for calculating the values of reduction of cutting fluid content in the cleaned samples with respect to its initial concentration were obtained. The main concepts of the proposed method were formulated. Its main advantage is its simplicity and the use of commonly available, inexpensive control and measuring equipment.

© 2021 Optica Publishing Group

PDF Article
More Like This
Contrast-dependent saturation adjustment for outdoor image enhancement

Shuhang Wang, Woon Cho, Jinbeum Jang, Mongi A. Abidi, and Joonki Paik
J. Opt. Soc. Am. A 34(1) 7-17 (2017)

Image contrast immersion method for measuring refractive index applied to spider silks

Douglas J. Little and D. M. Kane
Opt. Express 19(20) 19182-19189 (2011)

Measurements of absolute concentrations of NADH in cells using the phasor FLIM method

Ning Ma, Michelle A. Digman, Leonel Malacrida, and Enrico Gratton
Biomed. Opt. Express 7(7) 2441-2452 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.