Abstract
In this Letter, we investigate the possibility of using a commercially available -switch-pumped supercontinuum (QS-SC) source, operating in the kilohertz regime, for ultra-high resolution optical coherence tomography (UHR-OCT) in the 1300 nm region. The QS-SC source proves to be more intrinsically stable from pulse to pulse than a mode-locked-based SC (ML-SC) source while, at the same time, is less expensive. However, its pumping rate is lower than that used in ML-SC sources. Therefore, we investigate here specific conditions to make such a source usable for OCT. We compare images acquired with the QS-SC source and with a current state-of-the-art SC source used for imaging. We show that comparable visual contrast obtained with the two technologies is achievable by increasing the readout time of the camera to include a sufficient number of QS-SC pulses.
© 2017 Optical Society of America
Full Article | PDF ArticleMore Like This
Tai-Ang Wang, Ming-Che Chan, Hsiang-Chieh Lee, Cheng-Yu Lee, and Meng-Tsan Tsai
Biomed. Opt. Express 10(11) 5687-5702 (2019)
Peijun Tang, Shaojie Liu, Junbo Chen, Zhiling Yuan, Bingkai Xie, Jianhua Zhou, and Zhilie Tang
Opt. Lett. 42(23) 4974-4977 (2017)
Xiao Shu, Magalie Bondu, Biqin Dong, Adrian Podoleanu, Lasse Leick, and Hao F. Zhang
Opt. Lett. 41(12) 2743-2746 (2016)