Measurement of the nonlinear refractive index in optical fiber by the cross-phase-modulation method with depolarized pump light

Not Accessible

Your library or personal account may give you access

Abstract

Depolarized pump light is used in measurements of the nonlinear refractive index, n2, in optical fiber by the cross-phase-modulation method. High measurement repeatability within ±1% is obtained by this method. The nonlinear refractive index is determined for dispersion-shifted fiber, standard single-mode fiber, pure silica-core single-mode fiber, and dispersion-compensating fiber as 3.35 × 10−20, 2.96 × 10−20, 2.79 × 10−20, and 4.44 × 10−20 m2/W, respectively, at 1.55 μm. This shows that the nonlinear refractive indices of the optical fibers differ greatly according to glass composition.

© 1995 Optical Society of America

Full Article  |  PDF Article
More Like This
Estimation of nonlinear refractive index in various silica-based glasses for optical fibers

T. Kato, Y. Suetsugu, and M. Nishimura
Opt. Lett. 20(22) 2279-2281 (1995)

Single-pulse degenerate-cross-phase modulation in a single-mode optical fiber

Q. D. Liu, J. T. Chen, Q. Z. Wang, P. P. Ho, and R. R. Alfano
Opt. Lett. 20(6) 542-544 (1995)

Continuous-wave measurement of the fiber nonlinear refractive index

D. Monzón-Hernández, A. N. Starodumov, Yu. O. Barmenkov, I. Torres-Gómez, and F. Mendoza-Santoyo
Opt. Lett. 23(16) 1274-1276 (1998)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (2)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (3)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved